Boiler Flue Height Above Roof

Image Result For How Flue Height Above Flat Roof Roof Repair Flat Roof Repair Roofing

Image Result For How Flue Height Above Flat Roof Roof Repair Flat Roof Repair Roofing

Image Result For Distance House Twin Flue Stove Boiler Installation Roof Gas Boiler

Image Result For Distance House Twin Flue Stove Boiler Installation Roof Gas Boiler

Wood Stove Metal Flue Installation Diagram Wood Stove Chimney Wood Stove Wood Stove Fireplace

Wood Stove Metal Flue Installation Diagram Wood Stove Chimney Wood Stove Wood Stove Fireplace

Image Result For How Flue Height Above Flat Roof Roof Repair Flat Roof Repair Roofing

Image Result For How Flue Height Above Flat Roof Roof Repair Flat Roof Repair Roofing

Pin By David Troy On Fireplaces At Colesforfires Co Uk Wood Stove Chimney Wood Stove Wood Burning Stove

Pin By David Troy On Fireplaces At Colesforfires Co Uk Wood Stove Chimney Wood Stove Wood Burning Stove

Installation Advice Carron Stoves Direct Stove Installation Wood Burning Stove Boiler Stoves

Installation Advice Carron Stoves Direct Stove Installation Wood Burning Stove Boiler Stoves

Installation Advice Carron Stoves Direct Stove Installation Wood Burning Stove Boiler Stoves

The figures above are minimum clearances for typical domestic boilers.

Boiler flue height above roof.

As illustrated below if your flue exits through the roof within section a then you are required to rise at least 1800mm vertically above the roof surface and at least 600mm above the ridge. Back to our example over a run of 10 feet the roof would rise 40 inches. Additionally per our rule we need to add 2 feet or 24 inches giving us a total height of 64 inches. Homes built on varying terrain have their own set of chimney and flue regulations.

Flues need to be 600mm higher than the highest part of the roof within 3 metres. If your boiler flue has to face out onto a public space the installer will have to ensure that it s fitted at least 2 1 metres above ground level over head height. Vertical flues the majority of boiler flues exit out of a wall horizontally but if the flue from your boiler comes out at roof level then there are also some regulations that. If the pitch of the roof is 38 degrees or greater the termination point of the flue or chimney will need to be 2300mm horizontally from the roof line and roofing material.

From my very limited understanding of building regs part j for where the flue should be positioned i thought that the height of the top of the flue must be a minimum of 2 feet above the ridge. Vent caps 12 and smaller may terminate a distance above the roof if 8 feet or more away from a vertical surface as follows. Flues that are more than 3 metres away from the highest part of the roof need to be 1000mm above the flue penetration. The height of the chimney above the roof surface measured at the up slope side of the chimney from the roof surface to the chimney top should be at least three feet the green line in our photo.

This means that below 38 degree roof pitches that the height of the flue outlet should be at least 1800mm above the roof when not close to the ridge and above 38 degree roof pitches the flue outlet height should be 2300mm horizontally back to the roof flue height figures are given in the table above where the flue is not close to the ridge. 300 mm above ground roof or balcony level 2000 mm below a velux window for a vertical flue 300 mm above roof pitch or flat roof for a vertical flue note that more powerful boilers might require larger clearances between the flue and the relevant object. So take the top number of your roof pitch and multiply it by 10 then add 24 note example 1. This is a bit of an odd measurement and chimney clearance case because the chimney side is actually about 8 away from the roof edge.

Roof pitch rise run in inchesminimum height flat to 7 12 1 0 foot above the roof surface 7 12 to 8 12 1 5 feet above the roof surface 8 12 to 9 12 2 0 feet above the roof surface.

Woodstoveinstallation Wood Stove Wood Stove Fireplace Wood Stove Surround

Woodstoveinstallation Wood Stove Wood Stove Fireplace Wood Stove Surround

Pin On Wood Stove

Pin On Wood Stove

External Flue For Wood Burner Looks Like Neighbours Wood Burner Log Burner Limestone Fireplace

External Flue For Wood Burner Looks Like Neighbours Wood Burner Log Burner Limestone Fireplace

Gas Water Heater Dip Tube Gas Water Heater Hot Water Heater Water Heater Repair

Gas Water Heater Dip Tube Gas Water Heater Hot Water Heater Water Heater Repair

Source : pinterest.com